top of page
Discover the Latest in Biomedical Research Innovation
Search


How to Run an ANCOVA in GraphPad Prism (and How It Compares to Doing It with Sophie)
Hunted through Prism's Analyze menu for ANCOVA? It isn't there, and GraphPad's own FAQ confirms they've never shipped one. Prism can still do it, through two documented routes most users never find: the simple-linear-regression slopes test for the parallel-slopes assumption, and multiple regression with dummy-coded groups for the adjusted comparison. Here are both step by step, plus an honest comparison with describing the same analysis in plain language instead.
Aug 216 min read


Technical vs. Biological Replicates: The Pseudo-replication Trap That Sinks Papers
An audit of 200 published animal studies found only 22% had replicated the right thing, and 46% counted repeated measurements of one biological unit as independent samples. That error, pseudoreplication, inflates your n, shrinks your error bars, and manufactures significance that won't replicate. Here's what separates technical vs biological replicates, why the mistake inflates false positives, and what actually counts as a biological replicate in cell culture.
Aug 107 min read


The 5 Most Common P-Value Mistakes in Biomedical Papers (and How to Avoid Each)
When medical residents were surveyed on interpreting a p-value, 88% were confident they understood it and 100% got it wrong. That gap is why p-value mistakes survive peer review: nobody thinks they're making one. This piece covers the five most common errors in biomedical papers, several measured at scale in real journals: the inverse probability fallacy, the replication fallacy, 'trending toward significance', p-hacking, and treating 0.05 as a bright line.
Aug 38 min read


Cell Imaging Protocol: A Step-by-Step SOP for Quantitative, Analysis-Ready Microscopy
A no-fluff, step-by-step cell imaging protocol for microscopy images you can actually quantify. Eighteen numbered steps take you from Köhler setup and pixel calibration, through setting exposure on your brightest sample so nothing saturates, to acquiring the whole set under locked, identical settings. Works for brightfield, phase contrast, and fluorescence. Includes an equipment table, an acceptance-criteria checklist, and a troubleshooting table mapping each symptom to the s
Jul 296 min read


Effect Size Explained: Reporting Cohen's d and Why p-Values Aren't Enough
Your p-value can confirm an effect is real and say nothing about whether it's big enough to matter. Effect size answers that second question, and for a two-group comparison Cohen's d is the standard measure: the mean difference divided by the pooled standard deviation. This guide covers how to calculate and report Cohen's d, why to report it alongside every p-value and confidence interval, and how to interpret it without leaning on the 0.2/0.5/0.8 benchmarks that often don't
Jul 278 min read


t-SNE vs. UMAP for Single-Cell Data: The Guide to Dimensionality Reduction
Struggling to choose between t-SNE and UMAP for your single-cell data? UMAP has become the industry standard due to its speed and global structure preservation, but t-SNE still offers unique advantages for local granularity. This guide breaks down the mathematical differences, "Chari & Pachter" controversy, and proper parameter tuning to help you create scientifically accurate visualizations.
Apr 275 min read
bottom of page
